Innovative Fog and Misting Systems
Company Applications Gallery Products Contact Us Specifications Design Forms Distribution NEW PRODUCTS

Technical Information

Operation of the System

The nozzles and the auto drain valve may periodically become clogged due to minerals in the water. If necessary, remove them from the system and soak in Fogco Nozzle Cleaner for 30 minutes.

Always remove the nozzles and auto drain valve from the system during the winter months or if the system will not be used for a prolonged period of time. Flush the system before re-installing. Always drain the water from the pump if there is a danger of freezing.

The Slip-Lok system can be dis-assembled if replacement of the tubing or a fitting is required. To remove the tubing, place an open-end wrench over the tubing and slide it until it is against the fitting. Pull the tubing away from the fitting. Always cut the end of the tubing to obtain a clean edge before re-inserting.

If a leak develops at the point where the nozzle threads into a fitting, check to see that the o-ring is present and is not cut or torn. Replace the o-ring if necessary and re-insert the nozzle into the system. Never remove nozzles while the system is under pressure.

The Certified Series pumps have been tested by Underwriters Laboratory and Consultants Europe and are UL Approved and CE Certified. For additional information contact our Customer Service Department

Data Tables and Diagrams

The following Electric Data and Specifications tables provide additional specification information for the Premium, Certified, Professional, and Promotional pump ranges. Additional information is available upon request from our Customer service department.


Premium Series Electric Data and Specifications
Pump Model
60 Hz
Size
GPM
Motor
HP
Unit RPM Volts / Phase Full Load
Amps
Dimensions
Inches
Weight
lbs
96100 1 1 490 110-1 12.6 26 x 16 x 12 110
96120 1 1 490 220-1 6.3 26 x 16 x 12 110
96200 2 1.5 930 110-1 15 26 x 16 x 12 118
96220 2 1.5 930 220-1 7.5 26 x 16 x 12 118
96300 3 3 630 220-1 13.5 26 x 16 x 12 130
All pumps specified for pressure output of 1000 PSI/70 BAR. Feed line inlet pressure should not exceed 75 PSI/5 BAR. Contact Customer Service for custom design pumps and for specifications for pumps larger than 3 GPM or for 50Hz pump specifications.



Certified Series Electric Data and Specifications
Pump Model
60 Hz
Size
GPM
Motor
HP
Unit RPM Volts / Phase Full Load
Amps
Dimensions
Inches
Weight
lbs
92506 1 1 490 110-1 12.6 26 x 16 x 12 110
92676 1 1 490 220-1 6.3 26 x 16 x 12 110
92511 2 1.5 930 110-1 15 26 x 16 x 12 118
92677 2 1.5 930 220-1 7.5 26 x 16 x 12 118
92531 3 3 1475 220-1 13.5 26 x 16 x 12 130
Pump Model
50 Hz
Size
LPM
Motor
HP
Unit RPM Volts / Phase Full Load
Amps
Dimensions
Cm
Weight
kg
92541 4 1 530 220-1 7.3 66 x 41 x 30 50
92542 8 1.5 1060 220-1 11.2 66 x 41 x 30 54
92543 12 2 1590 220-1 13 66 x 41 x 30 59
All pumps specified for pressure output of 1000 PSI/70 BAR. Feed line inlet pressure should not exceed 75 PSI/5 BAR. Contact Customer Service for pumps specifications larger than 3 GPM/12 LPM.



Professional Series Pulley Driven Electric Data and Specifications
Pump Model
60 Hz
Size
GPM
Motor
HP
Unit RPM Volts / Phase Full Load
Amps
Dimensions
Inches
Weight
lbs
99100 1 1 460 110-1 14 21 x 16 x 11 92
99120 1 1 460 220-1 7 21 x 16 x 11 92
99200 2 1.5 920 110-1 17.4 21 x 16 x 11 100
99220 2 1.5 920 220-1 8.7 21 x 16 x 11 100
Pump Model
50 Hz
Size
LPM
Motor
HP
Unit RPM Volts / Phase Full Load
Amps
Dimensions
Cm
Weight
kg
98400 4 1 490 220-1 7.3 53 x 40 x 28 41
98800 8 1.5 980 220-1 11.2 53 x 40 x 28 45
All pumps specified for pressure output of 1000 PSI/70 BAR. Feed line inlet pressure should not exceed 75 PSI/5 BAR.



Professional Series Direct Drive Electric Data and Specifications
Pump Model
60 Hz
Size
GPM
Motor
HP
Volts / Phase Full Load
Amps
Dimensions
Inches
Weight
lbs
96025.OV .25 .5 110-1 7.4 8 X 22 X 10 55
92683.OV .5 .5 110-1 7.4 8 x 22 x 10 55
92505.OV 1 .75 110-1 14 8 x 22 x 10 60
92510.OV 2 1.5 110-1 17.4 8 x 22 x 10 65
Pump Model
50 Hz
Size
LPM
Motor
HP
Volts / Phase Full Load
Amps
Dimensions
Cm
Weight
kg
92921.OV 1.5 .5 220-1 3.6 20 x 56 x 25 25
92521.OV 4.5 1 220-1 6.2 20 x 56 x 25 27
92549.OV 8.9 2 220-1 9.7 20 x 56 x 25 29
All pumps specified for pressure output of 1000 PSI/70 BAR. Feed line inlet pressure should not exceed 75 PSI/5 BAR.



Promotional Series Electric Data and Specifications
Pump Model
60 Hz
Size
GPM
Motor
HP
Volts / Phase Full Load
Amps
Dimensions
Inches
Weight
lbs
97100 1 .75 110-1 14 18 X 11 X 10 44
97150 1.5 1.5 110-1 17.4 21 X 11 X 10 62
97102 1 .75 220-1 7 18 X 11 X 10 44
97152 1.5 1.5 220-1 8.7 21 X 11 X 10 62
Pump Model
50 Hz
Size
LPM
Motor
HP
Volts / Phase Full Load
Amps
Dimensions
Cm
Weight
kg
97200 3.1 1 220-1 6.2 46 X 28 X 26 20
97250 4.7 1 220-1 6.2 53 X 28 X 26 26
All pumps specified for pressure output of 1000 PSI/70 BAR. Feed line inlet pressure should not exceed 75 PSI/5 BAR.




Company | Applications | Gallery | Products | Contact Us | Specifications | Design Forms | Distribution | Dealer Inquires | Mist System | Fog System | Links | Submit Your Link